One of our completed projects involving seismic protection systems in our country is the Salyan ASAN Service Center. The project was officially inaugurated by President Ilham Aliyev on April 18.
The product applied in this project consists of 12 elastomer bearings manufactured by MAURER. However, rather than providing seismic isolation for the building itself, these bearings were installed between the building structure and the steel structure positioned above it.
There are two key nuances to highlight here:
• Thermal Movement & Structural Integrity: The steel structure resting on the 12 elastomer bearings will move smoothly over the bearings during thermal expansion and contraction caused by temperature fluctuations (heat and cold). Consequently, this prevents cracks from forming at the ceiling joints.
• Cost & Material Efficiency: Thanks to the installed elastomer bearings, a significant reduction in the mass of the steel structure was achieved. Because the required displacement capability is accommodated by the supporting elastomeric bearings, there is no need to design an overly rigid steel structure. As a result, substantial savings in steel tonnage were realized.